Search results for "Fetal heart"

showing 8 items of 8 documents

CARDIAC PUNCTURE OF FETUS WITH HURLER'S DISEASE AVOIDING ABORTION OF UNAFFECTED CO-TWIN

1978

Adultmedicine.medical_specialtyFetal ResorptionMucopolysaccharidosis IFetal heartPuncturesDiseaseAbortionIduronidaseFetal HeartPregnancyPrenatal DiagnosisDiseases in TwinsHumansMedicineFetal DeathGlucuronidaseGlycosaminoglycansFetusPregnancyFetal deathbusiness.industryObstetricsInfant NewbornFollow up studiesInfantFetal ResorptionGeneral MedicineFibroblastsAmniotic Fluidbeta-Galactosidasemedicine.diseaseAnesthesiaFemalebusinessFollow-Up StudiesThe Lancet
researchProduct

Fetus acardius: two- and three-dimensional ultrasonographic diagnoses.

2001

Objective. To determine whether ultrasonographic detection of acardiac fetuses and diagnostic accuracy of related malformations improve with complementary use of two-dimensional ultrasonography, three-dimensional ultrasonography, and Doppler scanning. Methods. Three pregnant women with multifetal gestations who were found to have discordant fetuses on initial two-dimensional ultrasonographic scanning were subsequently scanned with three-dimensional ultrasonography and color Doppler ultrasonography. Results. Although the possibility of acardiac fetuses was entertained in all cases after two-dimensional ultrasonographic scanning, the diagnosis was confirmed, and the accuracy and extent of fet…

Adultmedicine.medical_specialtyTriplet gestationUltrasonography PrenatalFetal HeartPregnancymedicineHumansRadiology Nuclear Medicine and imagingMedical diagnosisArthrogryposisFetusPregnancyRadiological and Ultrasound TechnologyGastroschisisbusiness.industryObstetricsMiddle Agedmedicine.diseasePregnancy Trimester FirstGestationFemalePregnancy Multiplemedicine.symptomUltrasonographybusinessJournal of Ultrasound in Medicine
researchProduct

Clinical Experiences with Clamp Electrodes in Fetal Scalp for Simultaneous pO2 and ECG — Registration

1973

The development of a scalp electrode for continuous measurement of fetal mean tissue-PO2 and simultaneous registration of ECG respectively fetal heart rate has been described previously (1). The electrode mechanics and electronic equipment must be adapted to the various demands of the birth process and the labor room environment. The technical results are not yet refined, when unfavorable conditions prevail, artifacts may be anticipated. A brief review of the proceedings in electrode clamp measurements should be presented.

Continuous measurementFetusFetal heart ratemedicine.anatomical_structureClampComputer scienceScalpElectrodemedicineElectronic equipmentBiomedical engineering
researchProduct

Foetal ECG recovery using dynamic neural networks

2002

Non-invasive electrocardiography has proven to be a very interesting method for obtaining information about the foetus state and thus to assure its well-being during pregnancy. One of the main applications in this field is foetal electrocardiogram (ECG) recovery by means of automatic methods. Evident problems found in the literature are the limited number of available registers, the lack of performance indicators, and the limited use of non-linear adaptive methods. In order to circumvent these problems, we first introduce the generation of synthetic registers and discuss the influence of different kinds of noise to the modelling. Second, a method which is based on numerical (correlation coe…

Finite impulse responseComputer scienceMedicine (miscellaneous)Machine learningcomputer.software_genreSensitivity and SpecificityLeast mean squares filterElectrocardiographyFetal HeartPredictive Value of TestsPregnancyArtificial IntelligenceRobustness (computer science)HumansActive noise controlArtificial neural networkbusiness.industryModels CardiovascularPattern recognitionAdaptive filterIdentification (information)NoiseFemaleNeural Networks ComputerArtificial intelligencebusinesscomputerArtificial Intelligence in Medicine
researchProduct

Nerves projecting from the intrinsic cardiac ganglia of the pulmonary veins modulate sinoatrial node pacemaker function

2013

Rationale: Autonomic nerves from sinoatrial node (SAN) ganglia are known to regulate SAN function. However, it is unclear whether remote pulmonary vein ganglia (PVG) also modulate SAN pacemaker rhythm. Objective: To investigate whether in the mouse heart PVG modulate SAN function. Methods and Results: In hearts from 45 C57BL and 7 Connexin40+/GFP mice, we used tyrosine-hydroxylase (TH) and choline-acetyltransferase (ChAT) immunofluorescence labeling to characterize adrenergic and cholinergic elements, repectively, within the PVG and SAN. PVG project postganglionic nerves to the SAN. TH and ChAT stained nerves, enter the SAN as an extensive, dense mesh-like neural network. Neurons in PVG are…

Malemedicine.medical_specialtysinoatrial nodepulmonary veinsPhysiologyAdrenergicMice TransgenicStimulationIn Vitro TechniquesMiceFetal HeartBiological ClocksHeart Conduction SystemHeart RatePhysiology (medical)Internal medicineAtrial FibrillationHeart ratemouse heartmedicineAnimalsHumansSinus rhythmIntrinsic cardiac gangliaSinoatrial NodeSinoatrial nodebusiness.industryOriginal ArticlesMiddle AgedElectric StimulationElectrophysiological PhenomenaMice Inbred C57BLoptical mappingAtropinemedicine.anatomical_structureEndocrinologyPulmonary Veinscardiac arrhythmiasCatheter AblationCardiologyCholinergicFemaleGangliaElectrical conduction system of the heartCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiovascular Research
researchProduct

Assessing Complexity in Physiological Systems through Biomedical Signals Analysis

2020

The idea that most physiological systems are complex has become increasingly popular in recent decades [...]

information flowComputer sciencebrainMultivariate time series analysisGeneral Physics and Astronomylcsh:AstrophysicsData sciencelcsh:QC1-999Fetal heart rateFuzzy entropyEditorialmultifractalitymultiscaleSettore ING-INF/06 - Bioingegneria Elettronica E Informaticalcsh:QB460-466Autonomic nervous functionBrain; Cardiovascular system; Entropy; Information flow; Multifractality; Multiscalecardiovascular systemHypobaric hypoxialcsh:QInformation dynamicsentropylcsh:Sciencelcsh:PhysicsEntropy
researchProduct

Association of first trimester fetal heart rate and nuchal translucency with preterm birth.

2021

To evaluate whether first trimester fetal heart rate (FHR) and nuchal translucency (NT) associate with preterm birth (PTB).This was a comparative case-control study of 518 normal pregnancies with no history of PTB, of which 272 delivered at term (TB) and 246 progressed to spontaneous PTB prior to 37, 34, 32, and 28 weeks. Fetal heart rate (FHR) and NT values at the first-trimester scan were compared by means of univariable (Mann-Whitney) and multivariable logistic regression analysis considering hourglass membranes (HM) as the most severe PTB subgroup. Finally, severity trends for both parameters were investigated using correlations with gestational age (GA) at delivery and Kruskal-Walls te…

medicine.medical_specialty030219 obstetrics & reproductive medicinebusiness.industryObstetricsInfant NewbornObstetrics and GynecologyHeart Rate Fetal03 medical and health sciencesFirst trimesterPregnancy Trimester First0302 clinical medicineFetal heart rateFetal HeartNuchal translucencyPregnancyCase-Control Studiesembryonic structuresPediatrics Perinatology and Child HealthMedicineHumansPremature BirthFemale030212 general & internal medicinebusinessNuchal Translucency MeasurementThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct

Role of microRNAs in fetal heart development and in isolated cardiac progenitor cells

2012

microRNAfetal heart developmentSettore BIO/16 - Anatomia Umanacardiac progenitor cells
researchProduct